"author": {
ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. Would I suspect this is a defective motor? Date Listed: 18/02/2023; . You will have live wires exposed and they can kill you if you touch them. I bought a new timer and replace the T104 timer clock. The rest of your setup is probably fine. The yellow clock face should sit down in the timer. I noticed that they had stopped. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. Move the start and stop pins to appropriate times for swimming pool filter operation. If not, that sounds like a weak/bad motor. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). I have the PF1202T timer on my pool. i would like to use a timer but am now afraid to try another. The timer not working is for the pump. Any guidance on how to fix this? There are many reasons why your pool timer may not be working. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). It should sit down nicely. Look to see if the clock is set to the correct time. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. Any ideas? Pools are not cheap! It is an ON tripper right? Grab it, pull it towards you, move it around then place it back down. Just turn the timer wheel until the correct time of the day is aligned with the timer marker that is mounted in front of the wheel. I have a white, red, and black wire coming from the power source. Repeat the process for the "on" pin. If you dont have the voltage here you have an issue with either the wiring or the breaker. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. Ordered new ones. Tighten them with a wrench. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. Then remove the mechanism by pressing the clip at the top of the timer box. A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Could also be grit or insects inside of the gears of the clock motor. "publisher": {
"
Align the bar with the current time and push it back into place. Turn the metal bar until it contacts one of two plastic side tabs. Any help is greatly appreciated. There is a second switch between the breaker and the timer. Just some ideas. Pop-in a new timer mechanism, and replace the wires to the previous configuration. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. The position of the metal bar forces the gear next to it to turn one way or another. Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. Southern Queensland Country Tourism CEO Peter Homan says water park could convert 'day trippers' to overnight visitors to Toowoomba The region's peak tourism body has claimed a widely requested water park could increase Toowoomba's appeal to a new era of visitors, as council says a park was not a priority in the coming decade. Put a meter on the wires or trace them back to find out their voltage and source. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. Wired correctly, #10 wire, nothing. Just installed a new timer. Turn the power off at the breaker box and carefully remove the wires to the clock. "address": "",
AJH Trade Group also participate in other affiliate programs. I have a T104. Is it Necessary? Or the switch can suffer wear over many years, and might not make solid contact. Perhaps bad wiring or a bad breaker is to blame. This div height required for enabling the sticky sidebar. Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. "headline": "Intermatic Pool Timer Troubleshooting",
Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. the trippers are even slightly damaged the timer won't work correctly. Other than a couple of weeks, we have spent fifteen years manually turning on our pump. Sometimes its way quick just to replace it rather than spend hours troubleshooting. Found the answer. But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on. Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. It I set the timer again it will jeep time until it gets to the next dog ear. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . Can I spray the timer while there is electricity going in the timer box? Hello, newer pool guy here. Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. please help me. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. T104 mechanisms (without the box) are cheaper than buying the mech + box, but if your box is old with rusty hinges, missing gaskets, latch that wont work, it may be best to replace the box as well. You should be able to see the gears moving. Like # 8 09-16-07, 03:09 PM nap New Member Join Date: May 2006 Location: north Posts: 4,162 when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. Hi Rhomell, are you sure you got the correct trippers? If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. Ideally, the switch would be placed after the timeclock, not before. David, check the wiring, the power in and power out wires may be reversed. Hi Rich, is one of those wires (white?) Resolved! No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. There is a switch control panel and replaced the 20amps DP switch as well. I have a PF1112T. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). 120Volt Tork 1101 timers can be fixed with repair parts. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. Hi Davey, Pool timers can also be used to automatically turn on/off pool lights or other outdoor lighting around the pool. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. Electricity is dangerous and can kill you if you dont know what youre doing. "@type": "ImageObject",
The problem lies, where the power dies, as they say, Thanks for the response. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. A timer replacement would be required. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. Same goes for slipping timer dogs! The 2,810 sq. Theres power to the pump using the manual override. To do this, pull the yellow-faced time dial (clockface) toward you. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. Hi Matthew T104 can only turn one pump on and off. Switch the breaker off at the power board. If your Intermatic swimming pool timer has stopped working you will have to do something called troubleshooting. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. The problem is the 'off' tripper. GFCI breakers trip at a very low threshold, doesnt take much. The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. Thanks in advance! Do not remove the screws from the trippers. Any idea what may be causing this? I have a inground pool with T10003RT4 control panel. Did you try to flip the switch of the timeclock? I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. If you cant see an issue with the gears, then it could be the timer motor. Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. It would not reset itself and could not get power back to the timer. Ill do the same. I have an intermatic timer thats 2 years young. Is there a separate switch somewhere between breaker and timer? It could also be loose wires, either on the time clock terminal board, or on the timer motor. The back of the timer dog has a tab that flips the switch, check the alignment of both, the dog may not be contacting the switch with enough surface to flip it on? A couple of weeks in, I noticed it was not keeping time. The other gears are not and the pump will not turn on or off unless done manually. A power surge may have taken out the timer or the pump. I called Intermatic and there is nothing you can do except check it every time you have a power loss. Proceed to step 4 to check the timer itself. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. It may or may not reduce the noise level however. AJH Trade Group is a participant in the Amazon Services LLC Associates Program. This page is fantastic!! Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. This product is certified by Amazon to work with Alexa. I have a sweeper set on auto on the second timer and it is working correctly. Assuming the wiring is all correct. It stays on until I turn off the circuit breaker. Hi Sandra, does the on/off tab switch crisply, or softly? Ive seen it happen from lightning strikes, or insect infestation. "dateModified": "1/10/2020",
The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. MLS # 6354744 Line is incoming, Load goes to the pump. Stupid third question, but does the ON tripper say ON? Many thanks! "@type": "Person",
Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. Still no luck. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Is it keeping time normally? Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). 240V out of the timeclock (Load/Load terminals) and nothing on the motor terminal board? Replaced complete new timer assuming 5 years perfect service probably wore it out. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . Same way, WD-40 or any light lubricating oil. It only takes a small amount of dirt to foul up gears so look carefully. You can replace the entire mechanism or the gears. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. Basically 12 real life hours equals about 14 on the timer. The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. my pool cleaner timer dog is set between 8 am and 11 am, everything is working fine manually, except that the pool cleaning pump will not start by the timer dog setting the clock is set correctly and moving . (usually not). Back when I was a young technician I was taught to always look for the easy things and use all my senses. Sound right? Or may be bent and not come together. When the trippers are done up, you shouldnt be able to move them with your hands. This will disengage the dial from the . Check the motor, and be sure the label is not printed 50 hz. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. They should be straight, if not, replace them. Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. Slide it around the pool timer dial to the correct start time and re-tighten it. Hello have a question some what related. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
How can it keep time if lever is in off position (manual lever). Now Im having to turn my pool pump on and off manually. Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. Hi Doug, Check the wiring. I currently manually turn it on and off. Any ideas? You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. Is there a control board, PCB in the panel that could have problems? I fastened it very securely. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. But of the timer itself is bad you will need a licensed electrician to change the timer for you. Replace them if they appear to be bent. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. Karl, good question. You may need to adjust the meshing of the timer motor gear so it runs the clock. However, after several hours, maybe overnight, the associated breaker will trip. The most common pool timer used for inground pool pumps is the Intermatic time clock. The same happens prior to the timer reaching the off tripper. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Does the tripper work on other areas of the clock, like near the off tripper? Sometimes those are looped back to the control box. Hi, Davy, seeing lots of complaints here. The best pool timers allow you to keep your swimming pool spotless without needing to run your pump around the clock. If you use our referring links, it costs you nothing extra. screwfindinganame on June 18, 2013 at 11:36 pm Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. My pool timer is in the off position and it is still running. Or be loose and not making good contact. Paul, it could be that you got a 50hz motor, instead of a 60hz? Elite. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. Check that the TEST button has not popped out. Did I wire it incorrectly or did I just get a bad timer? No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped.