62. Will it start challenge! Cold weather starting of Kubota equipment I don't recall the deadman switch working like that, I thought it would only stop the engine if the tractor was moving. JavaScript is disabled. This sub Reddit is meant for everything and all things tractor and tractor related things. If there is any water mixed with the oil then the engine can stall. For almost a Month I could not start the Kubota Tractor, come to find out after testing every switch and relay on the tractor it is a plunger switch on the what Kubota calls the (speed control pedal in the owners manual) (they should call it the Forward/Reverse pedal) Translators ? Air in the fuel line. called kubota and other parts places, they have no idea what it is, can't find a pic of it anywhere, so we just put a switch on it for now. You must log in or register to reply here. Charged the battery, Charged the battery, check the continuity on the fuses, traced power to the starter read more Chris (aka-Moose) Technician 363 satisfied customers 2015 Kubota 3350 w/cab . 63. This way you will get to know if the battery is dead. Can someone pinpoint where the fuel solenoid is located on the L3400HST? Thanks for this threadI was packing up today and this happenednever thought to mess with the pedal until I read this and it started up after a couple of pushes. Fuel flow issues are the most common reason for Kubota L3400 to stop working after running for a while. Changing Engine Oil. Try rocking the hydrostatic pedal back and forth, allowing it to return to it's functional position on it's own. I am going to talk about it elaborately in this article. I am thinking maybe the ignition switch? Make sure there is good voltage at the lift pump. If this is HST, rock your forward/reverse pedal back and forth while holding the key in the crank position. The air cleaner can be clogged or an unadjusted engine valve can cause this problem. Any chance a pto is engaged? Kubota Diesel Engine Troubleshooting - Bobby Ford Tractor & Equipment It was fine then. Put the solenoid back on and it would start but then die immediately. Kubota Tractor Don't Start? / Simple Trouble Shooting - YouTube No one here can tell you much more without more information from trouble shooting. 352K views 6 years ago if your Kubota tractor won't start watch this video - and try this first. 250 an hour?!? tank is 3/4 full, new fuel filter, my fathers friend came over and sprayed diesel in the intake and it started running a bit but soon as he stopped, engine stopped. So, you need to check the battery first if you are facing this kind of problem. Is your 3400 a hydrostat or standard shift transmission? L3400 won't start - help, please? - TractorByNet Can it be solved at home? or the starter engage, you need to know if it is the battery, or high resistance/ connection or something. Buts that's where the real. else. it should do the work. You must log in or register to reply here. I got this tractor from my grand father that passed last year, about 2800 hours on it, my fathers friend helped tow it over and has been sitting beside the RV under our car part since, it has been ran a few times with no issues. Most failures to start with what you have described is from a faulty safety switch or just being out of adjustment. 1. Check if it is dead or have any other problem. Put the solenoid back on and it would start but then die immediately. You must log in or register to reply here. Tight and clean them if necessary. The ignition lights and dash lights turn on with the key on but the engine does not turn over. OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. 64. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Fuel tank is half full. I have a Kubota L3400 with Manual transmission, 4WD. It may not display this or other websites correctly. Checking Engine Start System. Join us in searching for a Kubota diesel that will not start in the cold weather. L3200 Won't Start - Help!! | OrangeTractorTalks - Everything Kubota The other was the switch that senses the neutral position of the hydro pedal. shut down tractor in field, i even bushogged with it for 3 hours. Create an account to follow your favorite communities and start taking part in conversations. Press J to jump to the feed. I figured I needed to bleed the system. Disconnect the line which connects the fuel filter and the fuel pump. It needs to be properly functioned to do all the tasks is supposed to do. kubota L3500 cranks but won't start : r/tractors - reddit Still no idea what to do next. Kubota has no idea what it is, and i'm not going to the place that gave me that quote, we jumped it for now. Checked battery, fuses, fuel and all are good. Crack a line at an injector and see if you have fuel when cranking the engine. Ran the engine for 30 seconds and turned it off. The more I read about fuel solenoid the more I think my tractor non-run problem may be related to the fuel solenoid. Fix all the connections battery has with other parts of the vehicle. Thats where I would start, back on the battery. It just stuck. I am thinking the fuel solenoid is bad or could it be the relay not supplying enough power to solenoid to get it to work? 900 to tow it?!? JavaScript is disabled. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Established in 2009, we are the largest online community of Kubota tractor and equipment owners. The hold in coil is usually tied into low oil pressure, high temperature, sensors to shut the engine down if there is a problem develop when it's already running Not the clamp connections, directly on the post's have someone try to start the tractor, anything less than 10.5 or 11 volts indicates either a bad battery (high internal resistance, or sulphated) or a shorted/draggy starter. Unfortunately, not all tractor is perfect. Disconnect the two small wires you will find in the PTO lever. Battery is good. Today went to start the tractor and it won't start. Closed the air vent cock. With the wires plugged into each other you have the tractor thinking that the PTO is always disengaged, therefore it will start with the PTO engaged. Kubota is one of the most reliable agricultural vehicles to choose from. After some time, this cycle will start all over again. There can be a malfunctioning steering hydraulic cylinder that can cause the problem. So, if there is any link of blockage in it, it can also create a problem. Press J to jump to the feed. Battery fully charged, clicks when key is turned, but not engaging or spinning. Sorry for being late, thanks everyone for the replies, we worked on it all this weekend and finally got it, it's some kind of relay that controls the fuel cut off solenoid, it's not sending power to it anymore. My L2800 has done this since newjust not as much now, It has gotten better with age. kubota L3500 cranks but won't start (EDIT) not 3500, L3400, and i think he said it was a 2008 model. If voltages are all good when attempting a start, but starter will not engage, then battery voltage is not getting to the starter or the return path is high resistance/open. RUBYRUSS only posted a day ago that there was a problem with his L3200. Another common problem in Kubota is not getting started at all but just clicking. You must log in or register to reply here. Does the display say anything about OPC? It may not display this or other websites correctly. The issue is most likely another safety switch. You have found you high resistance problem. Kubota enthusiasts, hobbyists, and fans! Try to understand what is the problem first. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. When you load heavier the RPM shows down to an almost shiftless situation. Mostly this creates the problem. If you are facing any of those, do not worry. Why is the steering wheel spinning very easily? If your Kubota diesel engine does not start, begin by confirming that your electrical and fuel delivery systems are performing properly. Aug 9, 2021. Do it again if you feel needed. Battery fully charged, Curtis B., Technician 44,329 Curtis B., Technician 44,329 Satisfied Customers Any thoughts? 5 Most Common Kubota L3400 Problems (Solutions Included) Thanks for the Kubota books site. Charged the battery, check the continuity on the fuses, traced power to the starter Ask an Expert Car Questions Agriculture and Farm Equipment Is the concern it will not crank or it will not start? L3400DT W/ LA463 FEL and L235DT W/ BF400 Loader. Today it won't start. A battery starts with amps not volts. Any help would be appreciated. Continue with Recommended Cookies. Try what RockyRidge said, rock the HST pedal "sloooowly" with the key in the start positionmy L2800 used to do this fairly regularly and no it will not fail for the dealer if it is like mine it will get better, I haven't had to rock my pedal in many months. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. Fuel tank is half full. It will have issues over time as it is made for heavy-duty work. Spray DW40 on the rubberboot and work the PTO shift back and forth. Best Evergreen Trees to Plant In New York, 10 Evergreen Trees to Plant in North Carolina, 5 Common Problems with John Deere 4120 (Solutions Included), Most Common Problems with John Deere 5045E (Solutions Added), 6 Most Common Problems with Massey Ferguson 240, 5 Most Common Problems with Bobcat T770 (Solutions Included), Most Common Problems with John Deere 750 (Solutions Added). Welcome. L3450DT-GST, Woods FEL, B7100 HSD, FEL, 60" SB, 743 Bobcat with V2203, and more. Mechanic's Assistant: What is the complete model and serial number of your machine? Kubota Tractor won't startTry This - YouTube My Kubota l3400 tractor won't start. At the end of the fuel rail is a valve. Most times I get no click from the solenoid. You can face problems like the PTO not turning off even when the PTO lever is shifted to disengage. Kubota Starting Problems - YouTube Here are some of them you can face with the solution with it. Nonetheless, I'm the man of the farm, so this repair falls on me. The dash lights stay strong and do not dim when the key is turned. 63. if it is good, in other words it doesnt drop below about 11 volts. I thought with a dead battery I would hear clicking, when turning the key. if it is very low there, then by all means clean/repair the connections. Please post back. Then I tried to continue mowing, but I only made it down the hill and the tractor stalled as I made the turn. We have 5 Kubota L3400 manuals available for free PDF download: Workshop Manual, Operator's Manual . Definitely sounds like a fuel pump issue. .Sometimes it starts, then dies. Mechanical: Chassis: 4x2 2WD : 4x4 MFWD 4WD: Differential lock: rear standard: Steering: Check that the fuel shutoff solenoid is getting voltage before you go blaming the pump. For a better experience, please enable JavaScript in your browser before proceeding. Here are the symptoms: It could still be the battery. As we also learn about what makes them so reliable, and how to properly start and take care of your small. Kansas, Butler county, Just east of DooDah. Not starting, shutting off after some time, POT not turning on, and RPM slowing down are the common kubota l3400 problems. Replace the oil with some light oil. Thanks to all of you who responded. Maybe try jumping the starter just to see if it turns over. The fuel solenoid is not clicking when the key is turned. Kubota L3400 starter won't engage. Kubota L3400 is a farmers tractor which is a very vital part for some of them. Standard Transmission. Kubota L3400 starter wont engage. Battery fully charged, - JustAnswer BUT when you said a humming sound, I bet its the battery dropping under load and you are hearing a relay trying to pull in. Dead battery? The Shuttle Shift lever is stuck in the middle- it will not go into H/L/Reverse. It may not display this or other websites correctly. And yes, some of them can be solved at home. what I found was that not enough. It appears to be in Neutral, but is not and will not start after I turned the switch off. Kubota L3540 Won't Start : r/kubota - reddit.com Kubota is a brand of tractor that is very much reliable for many kinds of agricultural work. Thanks for the replies. Ask an Expert Car Questions Agriculture and Farm Equipment This answer was rated: Kubota L3400 starter wont engage. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. To fix this problem, you need to lean the fuel bowl first. If its still on, check for the cable which runs from the PTO shift and goes into the transmission case under the seat. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. Was asked to take a look at this problem and was solved by installing Starter Relay Kit That he bought from john deer but will work on any tractor I would think. JavaScript is disabled. My relatively new (71 hours) Kubota L3400 will not start. The other switches to look for are on the clutch pedal, on the range shifter if it is a standard shift or one just above the center of the floor board if it is a hydrostat. Or if there is any faulty safety switch, it needs to replace too. Got up the next day, no start. Kubota L3540 Won't Start. They wanted 110ish for the shop manual for my L2501. I did try the fuel solenoid after I removed it and the rod does not move when starting the tractor. You need a multimeter to start checking voltages. People need to turn off the vehicle to operate it again. Injection pumps rarely fail. Welcome. Removed the solenoid and the tractor started, had to restrict airflow since the fuel solenoid was not connected.. THe tractor will turn over but will not start. For a better experience, please enable JavaScript in your browser before proceeding. It doesn't even attempt to start. Check the Deadman switch under the seat? LOL. Then check the wiring. I hope this article has given you a solid idea of where to start. But today when I turned the key to start, no click, only the sound of the starter turning. Is the large wire on the starter near 12.6 volts? Once i had it running with the fuel solenoid out I had to get the tractor to turn off so I engaged it into gear and stood on the brake which shit the tractor off. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. Reading battery voltage with no load, does not tell the whole story. Separating Rear Axle Case from Brake Case, Manual Transmission and Glide Shift Transmission, Double Acting Type 2 (Floating with Detent), Electronic Instrument Panel (Intellipanel), Testing, Setting and Adjusting by Electronic Instrument Panel (Intellipanel), Checking GST Electric Control System (GST Model Only), Air Conditioner Relay, Blower Relays and Compressor Relay, R134A Refrigerant Recovery and Recycling Machine, Air Conditioner System and Front Windshield Wiper10-S31, Disassembling Differential Gear Assembly (L2800), Disassembling Differential Gear Assembly (L3400), Checking High Pressure Relief Valve Pressure, Separating MID Case from Transmission Case, Hydraulic Pump Test Using Flow-Meter (Power Steering), Hydraulic Pump Test Using Flow-Meter (Three Point Hydraulic System), Relief Valve (for Three Point Hydraulic System), Hydraulic Pump (Three Point Hydraulic System), Kubota L3400 Operator's Manual (94 pages), Care of Danger, Warning and Caution Labels, Instrument Panel, Switches and Hand Controls, Foot and Hand Controls (Manual Transmission Type), Warm-Up Transmission Oil in the Low Temperature Range, Do Not Operate the Tractor at Full Speed for the First 50 Hours, hangssig Lubricating Oil for New Tractors, Travel Adjustment/Suspension Adjustment Knob, Head Light/Turn Signal/Hazard Light Switch, Main Gear Shift Lever & Range Gear Shift Lever [Manual Transmission Type], Range Gear Shift Lever (L-M-H) [HST Type], Unlock the Parking Brake and Slowly Release the Clutch, Depress the Speed Control Pedal [HST Type], Make Preparations for Attaching Implement, Hydraulic Control Unit Use Reference Chart, Liquid Weight Per Tire (75 Percent Filled), Cleaning Grill, Radiator Screen and Oil Cooler, Checking Gauges, Meter and Easy Checker (TM), Cleaning Air Cleaner Element [Single Element Type], Replacing Hydraulic Oil Filter/Replacing Transmission Oil Filter [HST Type], Checking HST Oil Line [HST Type]/Checking Power Steering Line, Every 800/1500/3000 Hours and Every 1/2 Year, Flush Cooling System and Changing Coolant, Handling Precautions for Electrical Parts and Wiring. 61. Press question mark to learn the rest of the keyboard shortcuts. Checking Wheel Bolt Torque. I had two separate things affect starting on mine. So run the battery voltage test again. Pulled fuel cut off solenoidstarts. Make sure there's flow through the fuel system, start at the filter, then the lift pump, then injection pump, then injectors. You have found you high resistance problem. I had it going on Wednesday for about 20 to 30 minutes pushing snow, and then came back a few hours later to do some more work, and it wouldn't start. I disconnected the two wires and plugged them into themselves and it started right away now it doesn't turn over at all. Read somewhere that the fuel solenoid can cause the issue. Thanks, thats what it was, the solenoid wasen't getting power, we worked on it all weekend, some weird relay thing died and isn't sending power to the solenoid. Please explain what you mean by 'won't start': will the starter turn at all or is it all completely dead? Electrical System Check Electrical issues are among the most common reasons for engines not starting. The fuel solenoid is not engaging. Kubota L3400 tractor overview. I had it going on Wednesday for about 20 to 30 minutes pushing snow, and then came back a few hours later to do some more work, and it wouldn't start. You are using an out of date browser. For a better experience, please enable JavaScript in your browser before proceeding. After that, it will pick it up in about a minute or so. What does hang up is the PTO safety hookup on the PTO lever itself ( right side of wheel). Kubota L3400 2006 will turn over but not start. If the tractor starts off good, works for some time, and suddenly stops while in use, the most common reason is fuel starvation. Two weeks ago is the last time I used my L3400. But what is the problem which can appear in front of you? I always heard a click when when I turned on the key. For a better experience, please enable JavaScript in your browser before proceeding. If it's the fuel shut off, disconnect it or block the thing so it will not shut off the fuel. Turned on the engine and let it idle for a few minutes until it sounded better. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. if its filled with dirt and thick mud-like object, you need to replace the filter. My Kubota L3400 is failing to start. When key is turned to the first There are several ways to solve this problem. My Kubota l3400 tractor won't start. Charged the battery, - JustAnswer Check the gear compartment if something like stone or dried mud had stuck there. Many thanks. It is a multipurpose tractor that you can use in various ways. Lights can still work with a dead (actually low voltage) battery. For almost a Month I could not start the Kubota Tractor, come to find out after testing. It may not display this or other websites correctly. The consent submitted will only be used for data processing originating from this website. I followed the ignition procedure, indicator lights are fine, but when I turn the key I just get one beep followed by nothing, no clicks, nothing. Thats usually me. Sometimes it well run for a few seconds other times a few minutes. The ignition lights and dash lights turn on with the key on but the engine does not turn over. JavaScript is disabled. If you have 12V then have someone turn the key on while you listen to see if it starts. My 3400 HSt was new in dec 2006 and recently developed an intermittent starting problem, sometimes it would go etc.. My Kubota l3400 tractor won't start. Does that include lube? I got this tractor from my grand father that passed last year, about 2800 hours on it, my fathers friend helped tow it over and has been sitting beside the RV under our car part since, it has been ran a few times with no issues. Both have to be in neutral. Luckily, all these parts are much less money than just one hour of labor. he kinda thinks the fuel pump went out, any way to test that, anything else i should do next, don't really know to much about tractors, but the only tractor place we have around here wants $900 to tow it, and $250 a hour to work on it. You can find it by following the fuel line back from the injection pump and the first thing you run into with wires is likely the lift pump. / Simple Trouble Shooting RudydaGoat 163 subscribers Subscribe Share 54K views 3 years ago Just on that one mission i learned lots. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. My pantleg occasionally catches the PTO lever on my L3400. The safety switch on the foot pedal has been a problem. You will feel like this is a new vehicle you are running. Try cleaning your battery post and ground cable. What this does is, it pulls the fuel and takes it to the engine from the fuel tank. Or bad battery connection(s). 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. You need to get a service book for this tractor with a wiring diagram. I have a Kubota L3400 with Manual transmission, 4WD. The - JustAnswer It happens when the spring load is seized up and does not slide properly. Anyone have any ideas on what to do next? Shutting of Suddenly Arter Working for a While. Do it for at least fine munities. Check for voltage there and if not figure out why. Every 100 Hours. Kubota Tractor won't start. | Tractor Forum Read somewhere that the fuel solenoid can cause the issue. Mine has a switch for each of the two gear shift levers. L3400 won't start | OrangeTractorTalks - Everything Kubota Or maybe one of the PTOs are engaged? (EDIT) not 3500, L3400, and i think he said it was a 2008 model. You are using an out of date browser. Replaced the stop relay but still get same results. I disconnected the two wires and plugged them into themselves and it started right away now it doesn't turn over at all. The battery is brand new. I replaced the switch watch that video here: https://www.youtube.com/watch?v=TT0QN_xReOM The switch I got was for a 2013 L3800 Kubota TD-060-53902 yours may have a different number I did see some online but I would check your local Kubota dealer first. If not try the second one. I turned the air vent cock to open. Put new solenoid on.no start. Fuel flow issues are the most common reason for Kubota L3400 to stop working after running for a while. Open it, start it and let it run for a few minutes then close it. Evacuator Valve. You're not getting fuel to START the machine because they tie that pull in coi l into the safety switches in the START circuit. Battery is good. The issue would not be in your PTO switch if you have it plugged into each other. Thank you Wolfman.
Carbs In Arby's Fish Sandwich No Bun,
Korina Emmerich Net Worth,
Articles K